May 2009 AfiFree Terminal 155i Installation Manual 67
At the conclusion of software upload, each AfiFree 155i milk meter
automatically enters Cleaning mode and the display shows CL followed by the
stall number.
Recovering from a Malfunction during Data Upload
There are two options for recovery:
Wait at least 5 minutes.
In a shared parallel parlor, software upload restarts automatically.
In a parallel parlor with entrance identification, software upload restarts after
you open the exit gate.
Perform a manual update (see Manually Uploading Milk Meter Software below).
Manually Uploading Milk Meter Software
1. Open AfiMen.
The AfiMen Real Time window (Figure 33) appears.
2. Select the Milk tab.
3. Click to enter ―Test‖ mode.
4. Select the Track tab.
5. Click .
The Password dialog box appears.
6. In the Password dialog box, type afi and click OK.
7. Navigate to C:\AfiGoat\Data\Hex or C:\AfiSheep\Data\Hex.
8. Open the desired software file (you can only select one at a time).
The name of the software file for the AfiFree155 bodies begins FM1 (Figure
36).
The name of the software file for the Terminal 155i begins MT1 (Figure 36).
The update starts.
The blue bar in the AfiMen Real Time window indicates the progress of the
update. The update takes about 5 minutes.
Figure 36: AfiFree 155i Software Files